Welcome to our websites!

Forged Steel Gate Valve

Short Description:

1. Standard: API 602, BS5352, API 598/600 2. Pressure: 1.0 x 2.5MPa
3. Dimensions: DN50 plus DN600; 1/2′-24’4.
Materials: WCB, copper,
brass, non-rust steel 5.
Type: Rising stem, BB, FB, OS-Y 6. Operating temperature: 0 to 80 degrees C
7.Medium: water and oil and gas, etc. 8. Operation: handwheel. Gear equipment, electrical, etc


Product Detail

Product Tags

Forged Steel Gate Valve

1.Standard: API 602,BS5352,API 598/600
2.Pressure:1.0~2.5MPa
3.Size:DN50~DN600;1/2’’-24’’
4.Material:WCB,Bronze,Brass,Stainless steel
5.Type: Rising Stem, BB, FB, OS&Y
6.Operating temperature :0~80℃
7.Medium: water oil gas and so on
8.Operation: Hand Wheel. Gear Devices, Electric, Etc

Description

Applicable Standards:
Design and Manufacture: API600
Face to Face and End to End: ASME B16.10
Flanged End: ASME B16.5/ASME B16.47
Butt Welded End: ASME B16.25
Test&Inspection: API598
 
Design Description:
Full bore design
Outside Screw and Yoke(OS&Y)
Bolted Bonnet(BB)
Flexible wedge,fully guided
Solid or split wedge gate
Renewable seat rings
Forged T-head stem
Rising stem and non-rising handwheel
Flanged or butt welding ends
Available with bevel gear operator

Specification

No.

PART

ASTM Material

   

A105

LF2

F11

F304(L)

F316(L)

F51

1

BODY

A105+SS304

LF2

F11

F304(L)

F316(L)

F51

2

DISC

F6a

F6a

F6a+STL

F304(L)

F316(L)

F51

3

STEM

410

410

410

304(L)

316(L)

F51

4

GASKET

A105

LF2

F11

304+Graphite

316(L)+Graphite

316(L)+Graphite

5

BONNET

304+Graphite                             B16

F304(L)

F316(L)

F51

6

BOLT

B7

L7

F11

B8(M)

B8(M)

B8M

7

PACKING

Flexible Graphite

8

GLAND

A182 F6

LF2

F11

F304

F304

F304

9

GLAND FLANGE

A105

LF2

F304

F304

F304

10

NUT

A194 2H

8

11

EYEBOLT

A193 B7

B8

12

STEM NUT

A276 410

13

LOCK NUT

AISI 1035

14

NAMEPLATE

AL

15

HANDWHEEL

ASTM A197

Precautions for Installation of Steel Gate Valve

The hand wheel, handle and transmission mechanism are not allowed to be used for lifting, and collision is strictly prohibited.
Double gate valves shall be installed vertically (i.e. the valve stem is in the vertical position and the handwheel is at the top).
The gate valve with bypass valve shall open the bypass valve before opening (to balance the pressure difference at the inlet and outlet and reduce the opening force).
The gate valve with transmission mechanism shall be installed according to the provisions of the product operation manual. 5. If the valve is often opened and closed, lubricate it at least once a month.


  • Previous:
  • Next:

  • Write your message here and send it to us